A blank flange is one that is to be machined to a finished product. Flange Blank,Blank Pipe Flange,Blank Off Flange,Flange Blanking Plates Fuyuan Marine Accessories Co., Ltd , https://www.fuyuanmarineparts.com
Anti-corrosion and verification method for explosion-proof integrated temperature transmitter
The explosion-proof integrated temperature transmitter is a commonly used measuring instrument. The product adopts integrated design, the structure is simple and reasonable, and can directly replace the ordinary assembled thermocouple and thermal resistance, and is widely used in many fields. The transmitter is composed of a reference unit, an R/V conversion unit, a linear circuit, a reverse connection protection, a current limiting protection, a V/I conversion unit, and the like. After the temperature-measuring thermistor signal is converted and amplified, the nonlinear relationship between the temperature and the resistance is compensated by the linear circuit, and a constant current signal of 4-20 mA which is linear with the measured temperature is output after the V/I conversion circuit.
Anti-corrosion method for explosion-proof integrated temperature transmitter:
1. If it is a newly purchased transmitter (within half a year) and eliminate its own fault, it is recommended to check whether there is a strong magnetic field around it and whether the fluid is stable (unstable or not).
2. If the transmitter is more than half a year, or the measured medium is not clean or corrosive, the bearing may be worn. The filter should be installed upstream of the transmitter to replace the internal impeller. It also needs to be recalibrated because the repeatability of the transmitter generally does not maintain the factory characteristics after half a year.
Explosion-proof integrated temperature transmitter verification method
1. When used in explosive hazardous areas, please pay attention to the explosion-proof mark and protection level;
2. The installation environment must be within -20-+70 °C. When the ambient temperature is too high, the WZ/R signal converter and display module can be installed separately from the thermal resistance or thermocouple. Special explosion-proof box with separate mounting transmitter.
3. Before powering up, please check the positive and negative polarity of the power supply carefully, and you can't connect the wrong ones, otherwise it may cause unpredictable consequences.
4. The W signal converter module is potted and cured with epoxy resin to enhance its anti-shock performance and prevent moisture, corrosion and moisture.
5. Check after six months of use.
The above is the verification method of the explosion-proof integrated temperature transmitter. Through the above introduction, the user has a certain understanding of the calibration method. It can ensure the measurement results are more accurate and can avoid the occurrence of faults during use.