Quartz tube level gauge common fault solution


Quartz tube level gauge routine inspection and troubleshooting methods, this method is suitable for magnetic flap level gauge, two-color quartz tube level gauge, glass tube level gauge and so on.

1, first check whether the power is connected, if found incorrect connection should be modified according to the operating manual.
2. Use a three voltmeter to measure the voltage of +24V and O/PI Division. The voltage should be between 13V-36V. If the voltage is abnormal, you should check whether the line or related equipment is abnormal.
3. The second item should be confirmed after normal, and then in the 4-20MA loop string a milliamp meter, check the current is normal, if the current value is not normal should replace new products or contact customer service personnel.
4. Use a voltmeter to check the voltage between IN and COM. Normally it should be about 2.5V. If the voltage is too low, you should remove the EXC wire. If the voltage returns to normal, it indicates that the magnetic yellow module is abnormal, if the power is still low It means that the signal converter is damaged. If you find the above phenomenon, you should replace the signal converter or contact customer service personnel according to the actual situation.

The float fell to the bottom and the flag was not zeroed

The flag board cannot keep up with the speed at which the float ball descends. A throttling device should be added to slow down the liquid level. The flag color plate will not be flipped, or the color plate should be confused. Make sure that there are no magnetic bodies in the surrounding and internal parts of the body tube. After the clearance, use a magnet to sweep them once to make the colors uniform. The 360-degree flip float ball magnetic field is too strong, contact customer service personnel to replace the float.
The proximity switch does not operate. Check whether the switch operation is normal with the meter. When the magnet is close, the contact point should be turned on and the resistance should be less than 300M. After the magnet is removed, the switch should be open and the resistance should be more than 10MO. If it does not meet the above requirements, it should be replaced. New proximity switch.

Welding Rope

Tungsten carbide welding rope is a type of welding filler material that is used for hardfacing applications. It is made by combining tungsten carbide particles with a binding material, such as nickel or cobalt, to create a rope-like form.

Tungsten carbide is known for its exceptional hardness and wear resistance, making it ideal for applications where the welded surface needs to withstand extreme abrasion and impact. The welding rope is typically used in industries such as mining, oil and gas, construction, and agriculture.

When the tungsten carbide welding rope is heated during the welding process, the binding material melts and fuses the tungsten carbide particles to the base metal, creating a hard and durable surface. This helps to extend the lifespan of equipment and machinery by protecting it from wear and tear.

Tungsten carbide welding rope can be applied using various welding processes, including manual metal arc welding (MMA), gas tungsten arc welding (GTAW), and flux-cored arc welding (FCAW). The choice of welding process depends on the specific application and the equipment available.

Overall, tungsten carbide welding rope offers a cost-effective solution for protecting and repairing high-wear surfaces, making it a popular choice in industries where durability and longevity are essential.

Welding Rope,Ctc Sctc Welding Rope,Cast Tungsten Carbide Welding Rope,Spherical Tungsten Carbide Welding Rope

Luoyang Golden Egret Geotools Co., Ltd , https://www.hvafspray.com