Output Pluse Signal LCD Display Vortex Flow Meter for Measuring Water, Steam Description of vortex flowmeter: Product standard: Function: It can output pulse frequency signal or (4~20 ) mA standard current signal ,be equipped with the industrial automation instrument can display the instantaneous and accumulated flow rate to realize the function of measuring and controlling automaticly. Characteristics: It has the characteristics of widely range, high precision, low pressure loss. When measure the volume flow, there is no effect to density, pressure, temperature, viscosity, etc. It can be instead of the orifice meter and will hold the leading position in the future. Application fields: It is mainly used to measuring the flow rate of in liquids, gases and steam in the fields like oil, chemical industry, metallurgy, electric power, heat industries and municipal construction, environmental protection projects . we have a wide range of Classic wheels to fit both sport and luxury vehicles,whether you want to add a touch of classic JDM Wheels to your passenger car or improve its performance with a set of Retro Wheels,Our Car Aluminium Rims products will be one of your best choices.These classic wheels by H.R-TECH Wheels are a budget-friendly alternative to both damaged and exhausted factory wheels,it offers you time-honored classic design coupled with modern touches,the latest technology and excellent style come together to create an awesome product you deserve at a price you can afford.It is precision made for a consistent fit and perfect function, so you can enjoy your ride year after year. Our HRW Forged Wheels combines forward-thinking technology with time-tested design principles and techniques to make a wheel that meets your needs in every way. These wheels give you the classic look you desire while restoring your ride for much less cash, so you can save those extra dollars on a joyride! Classic JDM wheels,Car Aluminium Rims,Passenger Car Wheels,Retro Wheels HENAN RACE TRADING CO.,LTD , https://www.hrwheelsproject.com
Technology of vortex flow meter:
Model: LUGB series (flange type, sandwich type)
Size: DN25, 32,40,50,65,80,100,125,150,200,250,300
Nominal pressure: normal type          1.6 MPa
                              High-pressure type:  2.5 MPa, 4.0 MPa
Fluid temperature :normal type             (-40~300) ºC
                               High-temperature type  (-40~400 ) ºC
Accuracy : liquid         1.0,  Â
                 gas, steam   1.5
Measuring range: liquid         (1~10) m/s,
                            gas, steam   (5 ~ 50) m/s
Range scale:10:1- 20:1
Output signal: three~wire voltage pulse or (4~20 mA) standard current signal
Power supply: 24V DC (location indication can choose 3.6 V battery power supply optional)
Intrinsic safe explosion-proof: ExiaIICT1 - T4
Environmental conditions: temperature (-40~55) ºC
                                           relative humidity (5~90) %
                                           atmospheric pressure (86 ~ 106) KPa
Applicable medium: gas, liquid or steam
Feature of vortex flowmeter:
1. Widely measuring range. Can measure liquids, gases and steam and other kinds of fluid.
2. Powerful output function. It can output pulse frequency signal or (4 ~ 20) mA standards current signal and it can display the instantaneous and accumulated flow rate.
3. Little pressure loss. The measuring principle determined to low pressure loss, compared to other meter, it can conserve energy better.
4. High reliability. The structure is simple and reliable, no moving parts, high reliability, reliable running in long time.
5. High accuracy. Output is pulse signal which proportional to the flow rate, no zero drift, high accuracy.
6. Good reproducibility.In a certain range of Reynolds number, the frequence of the output signal is unacted on fluid physics characteristic and ingredient variation, meter coefficient just related to the figure and dimension of the swirl-generating body. There will be no compensation when measure the fluid volume rate.After change the accessories, the meter can still workable without re-calibration.
Â
Principle: The basic principle of vortex flowmeter is Carmen vortex phenomenon, when the medium flowing through the triangle with a certain speed, there are diplostichous regular swirl alternately in both sides of the triangle, the swirl arranged unsymmetrically in the downstream of the triangle, the piezoelectricity detector can detect the separated frequence of the swirl ,and according to the frequence can feflect the flow rate.
The quality standard is :JB/T9249-1999 , and according to ISO9001:2008 to control the quality.Each product has to inspect contain leak tightness test, shell strength test, insulation strength test, electrical aging test, water(gas) flow calibrate test, etc. We ask our supplier provide test report of raw material, each electrical element has to be detected, so every finished product has factory test report and data record.
DN(mm)
Water
Ambient temperature              Ambient pressure                                Air
Measuring Range (m 3 /h)
Measuring Range (m 3 /h)
25
1~10
8~60
32
1.5~15
14~100
40
3~30
18~180
50
4~40
30~300
65
6~60
50~500
80
13~130
70~700
100
20~200
100~1000
125
36~360
150~1500
150
50~500
200~2000
200
100~1000
400~4000
250
150~1500
600~6000
300
200~2000
1000~10000
Mass measuring range of superheated steam Â
DN (mm)
Lower Limit Flow Rate   (Kg/h)
Upper Limit Flow Rate (Kg/h)
DNÂ Â Â Â Â Â Â Â Â Â (mm)
Lower Limit Flow Rate (Kg/h)
Upper Limit Flow Rate   (Kg/h)
25
13.1
104
100
164.7
1647
32
23
184
125
247.1
2471
40
26.5
265
150
329.4
3294
50
49.4
494
200
658.8
6588
65
82.3
823
250
988.2
9882
80
115.3
1153
300
1647
16470
Mass measuring range of saturation steam Â
Absolute Press (MPa)
Temp. t(Celsius)
Density ÏÂ Â Â (Kg/m 3 )0.2
120.23Â
1.1290.3Â
133.54Â
1.6510.4Â
143.62
2.1630.5Â
151.84
2.6690.6Â
158.94Â
3.170.7Â
164.96Â
3.6670.8Â Â
170.41Â
4.1620.9Â Â
175.36Â
4.6551.0Â
179.88Â
5.1471.2
187.96
6.1271.5Â Â
198.4Â
7.6022.0Â
212.37Â
10.05
DN25Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Lower Limit
Upper LimitÂ
14Â
140Â
17
170Â
19Â
190Â
22
220Â
23Â
230Â
25Â
250Â
27Â
270Â
28Â
280Â
30Â
300Â
33Â
330Â
36Â
360Â
42Â
420
DN32         Lower Limit Upper Limit
Â
26
260Â
30Â
300Â
34
340Â
38Â
380Â
41
410Â
44
440Â
47Â
470Â
50
500Â
52Â
520Â
57
570Â
63
630Â
73Â
730
DN40Â Â Â Â Â Â Â Â Â Â Â Lower Limit
Upper LimitÂ
31
310Â
38
380Â
44
440Â
48Â
480Â
53Â
530Â
57Â
570Â
60Â
600Â
64Â
640Â
67Â
670Â
73Â
730Â
82Â
820Â
94Â
940
DN50
Lower Limit
Upper LimitÂ
52
520Â
63Â
630Â
73
730Â
81Â
810Â
88Â
880Â
95Â
950Â
101Â
1010Â
107
1070Â
112Â
1120Â
122
1220Â
136Â
1360Â
157Â
1570
DN65
Lower Limit
Upper LimitÂ
90Â
900Â
106
1060Â
121Â
1210Â
134Â
1340Â
146Â
1460Â
158Â
1580Â
168Â
1680Â
178Â
1780Â
187Â
1870Â
204Â
2040Â
227
2270Â
261Â
2610
DN80
Lower Limit
Upper LimitÂ
122Â Â
1220Â
148
1480Â
170
1700Â
188
1880Â
205Â
2050Â
221Â
2210Â
235Â
235Â
249Â
2490Â
261Â
2610Â
285Â
2850Â
318Â
3180Â
365Â
3650
DN100
Lower Limit
Upper LimitÂ
175Â
1750Â
212
2120Â
242
2420Â
269
2690Â
293
2930Â
315Â
3150Â
336Â
3360Â
355Â
3550Â
374Â
3740Â
408Â
4080Â
454Â
4540Â
522Â Â
5220
DN125
Lower Limit
Upper LimitÂ
262Â
2620Â
318
3180Â
363
3630Â
404Â
4040Â
440Â
4400Â
473Â
4730Â
504Â
5040Â
533Â
5330Â
561Â
5610Â
612Â
6120Â
681Â
6810Â
783Â
7830
DN150
Lower Limit
Upper LimitÂ
350
3500Â
423Â
4230Â
484
4840Â
538Â
5380Â
586Â
5860Â
631
6310Â
672Â
6720Â
711
7110Â
747Â
7470Â
815Â
8150Â
908Â
9080Â
1044Â
10440
DN200
Lower Limit
 Upper LimitÂ
700Â
7000Â
846Â
8460Â
969
9690Â
1076Â
10760Â
1173Â
11730Â
1261Â
12610Â
1344
13440Â
1421Â
14210Â
1494Â
14940Â
1630Â
16300Â
1815Â
18150Â
2088Â
20880
DN250
Lower Limit
Upper LimitÂ
1050Â
10500Â
1269Â
12690Â
1453
14530Â
1641Â
16410Â
1759Â
17590Â
1829Â
18290Â
2016
20160Â
2132Â
21320Â
2241Â
22410Â
2445Â
24450Â
2722Â
27220Â
3132Â
31320
DN300
Lower Limit
Upper LimitÂ
1750
17500Â
2116Â
21160Â
2422Â
24220Â
2690Â
26900Â
2932Â
29320Â
3153
31530Â
3359Â
33590Â
3553Â
3553Â
3736Â
37360Â
4076Â
40760Â
4536Â
45360Â
5220Â
52200